COMPARISON OF COLUMN AREAS

   
The carrying capacity of a column is primarily based on the gross area of the cross sectional (assuming the same amount of steel is used).
Use the table below to determine what size round column to substitute for a square column.
 
  SQUARE COLUMN SIZE (INCHES) GROSS AREA (SQUARE IN.)   ROUND COLUMN DIAMETER (INCHES) GROSS AREA (SQUARE IN.)  
  8 X 8 64   10 79  
  10 X 10 100   12 113  
  12 X 12 144   14 154  
  14 X 14 196   16 201  
  16 X 16 256   18 254  
  18 X 18 324   20 314  
  20 X 20 400   22 380  
  22 X 22 484   24 452  
  24 X 24 576   26 531  
  26 X 26 676   28 616  
  28 X 28 784   30 707  
  30 X 30 900   32 804  
  32 X 32 1024   34 908  
  34 X 34 1156   36 1018  
  36 X 36 1296   42 1385  
  42 X 42 1764   48 1810  
  48 X 48 2304   60 2827  
             
  Back to the Top      
             
  CONCRETE REQUIREMENTS  
     
  COLUMN DIAMETER (INCHES) CUBIC VOL CONCRETE PER FT OF HEIGHT   COLUMN DIAMETER (INCHES) CUBIC VOL CONCRETE PER FT OF HEIGHT  
  6" .0073   24" .1164  
  8" .0129   28" .1584  
  10" .0202   30" .1818  
  12" .0291   32" .0269  
  14" .0396   36" .2618  
  16" .0517   42" .3565  
  18" .0654   48" .4654  
  20" .0808   60" .7275  
             